- Party Group of the Shandong Energy Supervision Office of the Communist Party of China: Deeply promote the integrated construction of Shandong's power market
- State Power Investment Group holds a regular meeting on production and operation in March
- Focus | Electric Power Redemption and Transcendence on the Eve of Great Changes
- Preview of the Two Sessions | Use the power of the market to support energy transformation
Company News
Good news - Luli Group's 60MW steam turbine unit flow technology transformation and efficiency improvement service project has passed the energy conservation certification and engineering acceptance
2020Year1moon2On the morning of the day, our company's technical service project-Luli Group Co., Ltd.60MWThe comprehensive technical transformation and efficiency improvement project of the flow structure of the double-coagulation steam turbine unit has passed the energy conservation certification and engineering acceptance.
This project is implemented by our company through technical services to optimize and transform the unit flow structure system. The contract stipulates that the energy saving target is rated58MWUnder electric load conditions, the comprehensive efficiency increase ratio shall not be lower than4%, energy saving and efficiency improvement power supply shall not be less than2320kw/h。
Our company is2019Year12moon22On the day, the project construction was completed ahead of schedule, the one-time start-up was successfully turned on, and the grid was connected to produce electricity, and the unit was operated normally and stably. go through168Aging operation in hours,2020Year1moon1Day evening23:00Starting from1moon2Noon11:00Time ends, total time12In an hour, energy saving measurement work was carried out on site.
By comparing the steam consumption values under the same operating conditions before and after the transformation, the average steam consumption value measured before the transformation is6.05kg / kw.h, the average vapor consumption value measured after the transformation is5.62kg/kw.h, each electricity production1Kilowatt-hour steam saving0.43kg, the energy saving and efficiency increase ratio is7.1%, far exceeding the contract agreement4%Energy saving and efficiency improvement ratio. Rated58MWUnder the same operating conditions, the energy-saving power is4118kw/h, the energy-saving effect is significant and the economic benefits are considerable.
During the project construction process, our company carefully organized, scientifically designed, and implemented it strictly, and completed all node tasks with quality and quantity. It received unanimous praise from energy-consuming units, demonstrated our company's excellent corporate culture and solid work style, and won market reputation and service reputation.
Here, while warmly congratulations, I would like to express my sincere thanks to all the assisting units. At the same time, I welcome the potential energy-consuming units to visit and guide on the spot for win-win cooperation!